Serviceline Industrial Sensors
Serviceline Explosion Protection

Thermocouple Converter FB5205B3

FB5205B3
  • 4-channel
  • Inputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Converter for thermocouples and mV-signals
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Utdrag ur datablad: Tekniska data för  FB5205B3

Slots
Occupied slots2
Supply
Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies FB92**
Power dissipation0.75 W
Power consumption0.75 W
Internal bus
Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit
temperature input
Number of channels4
Suitable field devices
Field device [2]Thermocouple
Field device [4]mV source
Suitable sensors
Sensorthermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources
Connectionchannel I: 1+, 2-; channel II: 5+, 6-; channel III: 9+, 10-; channel IV: 13+, 14-
Measurement range-65 ... 75 mV with LFD , -75 ... 75 mV without LFD
Smallest span5 mV for 0.1 % accuracy
Linearity error0.1 %
Conversion timemax. 300 ms (4 channels) without LFD max. 600 ms (4-channel) with LFD
Compensation (reference junction CJC)internal cold junction compensation or external cold junction
Line fault detectioncan be switched on/off for each channel via configuration tool ,
Open-circuit> 1 kΩ
Transfer characteristics
Deviation
Influence of ambient temperaturemax. 0,1 %/10 K
Indicators/settings
LED indicationLED green: supply
LED red: line fault, collective alarm , flashing: communication error
Codingoptional mechanical coding via front socket
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-78
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 955 g
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
Data for application in connection with hazardous areas
EU-type examination certificatePresafe 19 ATEX 14058U
MarkingEx-Hexagon II 2(1)G Ex db eb q [ia Ga] IIC Gb
II (1)D [Ex ia Da] IIIC
I (M1) [Ex ia Ma] I
Input
Voltage1 V
Current71 mA
Power62 mW (trapezoid characteristic curve)
Galvanic isolation
Input/inputfunctional insulation acc. to IEC 60664-1:2007, rated insulation voltage 50 V, testing voltage 500 V
Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020
EN 60079-1:2014
EN 60079-5:2015
EN 60079-7:2015+A1:2018
EN 60079-11:2012
International approvals
ATEX approvalPresafe 19 ATEX 14058U
IECEx approvalIECEx PRE 19.0013U
Approved forEx db eb q [ia Ga] IIC Gb
[Ex ia Da] IIIC
[Ex ia Ma] I
General information
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210120
ECLASS 12.027210101
ECLASS 11.027210120
ECLASS 10.0.127210120
ECLASS 9.027210120
ECLASS 8.027210120
ECLASS 5.127210120
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.139121008

Details: FB5205B3

Datasheet: FB5205B3

DatasheetFile TypeFile Size
Datasheet FB5205B3PDF1099 KB
Datenblatt FB5205B3PDF1100 KB

Documents: FB5205B3

ManualsFile TypeFile Size
FB Hardware ManualPDF9157 KB
FB-Hardware-HandbuchPDF9182 KB
Instruction manuals
ИнструкцииPDF186 KB
Instruction manual / BetriebsanleitungPDF363 KB
Návod k poużitíPDF180 KB
Instruktions manualPDF179 KB
Instruction manualPDF189 KB
KasutusjuhendPDF174 KB
KäyttöohjePDF173 KB
Manuel d'instructionsPDF185 KB
BetriebsanleitungPDF186 KB
Οδηγίες χρήσηςPDF191 KB
HandleidingPDF181 KB
Instruction manual / BetriebsanleitungPDF179 KB
Használati útmutatóPDF181 KB
Manuale di istruzioniPDF181 KB
Lietošanas pamācībaPDF178 KB
Instrukciju vadovasPDF179 KB
Instrukcja obsługiPDF182 KB
Manual de instruçõesPDF182 KB
Manual de utilizarePDF181 KB
Návod na poużitiePDF180 KB
Navodila za uporaboPDF178 KB
Manual de instruccionesPDF183 KB
ManualPDF176 KB
Application reports
Application Report - Communication Redundancy for Uninterrupted OperationPDF529 KB
Application Report - LB and FB Remote I/O Systems for Digitally Connecting Analog Field DevicesPDF208 KB
Application Report - Space Saving Extension for Existing PlantsPDF300 KB
Application Report - Using Remote I/O Systems for the Efficient Digitalization of PlantsPDF371 KB
Applikationsbericht - Platzsparende Erweiterung für bestehende AnlagenPDF300 KB
Applikationsbericht - Redundanz der Kommunikation für ungestörten BetriebPDF530 KB
Applikationsbericht - Remote-I/O-Systeme Typ LB und FB für digitale Anbindung analoger FeldgerätePDF208 KB
Applikationsbericht - Remote-I/O-Systeme für effiziente AnlagendigitalisierungPDF365 KB

CAD+CAE: FB5205B3

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP7330 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ2207 KB

Approvals+Certificates: FB5205B3

CertificatesFile TypeFile Size
Brasil TUV Rheinland BrazilPDF1258 KB
China SITIIAS CCC Ex CertificatePDF2333 KB
Europe Presafe DNV GL II 2(1)G I (M1) ATEX II (1) DPDF607 KB
Presafe DNV GL IECEx Certificate of ConformityLINK---
United Kingdom CML UK-Type Examination Certificate UKEX Category (1) D UKEX Category (1) G UKEX Category (M1)PDF242 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)PDF1148 KB
EU Declaration of Conformity (P+F)PDF1141 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1142 KB
UK Declaration of Conformity (P+F)PDF1110 KB
EU Declaration of Conformity (P+F)PDF1138 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1140 KB
EU-Konformitäterklärung (P+F)PDF1142 KB
EU Declaration of Conformity (P+F)PDF1148 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1140 KB
EU Declaration of Conformity (P+F)PDF1141 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1140 KB
EU Declaration of Conformity (P+F)PDF1141 KB
EU Declaration of Conformity (P+F)PDF1143 KB
EU Declaration of Conformity (P+F)PDF1141 KB
EU Declaration of Conformity (P+F)PDF1140 KB
EU Declaration of Conformity (P+F)PDF1142 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1139 KB
EU Declaration of Conformity (P+F)PDF1141 KB